T60 TEMPERATURE SENSOR

This next generation ambient temperature sensor builds on the NRG 110S’s trusted design, offering improved temperature accuracy and long-term reliability in harsh environments.

CONFIGURATION OPTIONS

4.6m cable

13m cable

67m cable

90m cable

110m cable

13m Cable - Calibrated



Details

The NRG T60 Temperature Sensor brings a new sensing element to the NRG 110S’s time-tested form. The result is a durable, reliable sensor that offers reduced measurement uncertainty and is capable of capturing measurements at higher temperatures. Because the T60 maintains the same physical design, signal output, and wiring scheme as the 110S, transitioning to this next generation sensor is exceptionally easy.

The T60 is ideally suited for the temperature measurement requirements of remote wind and solar energy studies. Recommended uses of the data from this sensor include calculating energy density calculations; monitoring air temperature; calculating atmospheric stability conditions; identifying icing conditions in cold climates; and estimating PV panel efficiency, which is temperature dependent.

*Please note: T60C is the calibrated version of this sensor.

Benefits


  • Lower measurement uncertainty
  • ILAC-compliant, NIST-traceable calibrations available from an ISO 9001:2008, ISO/IEC 17025:2017 certified laboratory
  • Can measure up to 70°C (5°C greater than the 110S) 
  • Suitable for the temperature measurement requirements of remote wind and solar energy studies
  • Same physical design, body materials, and radiation shield as the 110S, ensuring seamless transition to T60

Specifications

  4.6m cable (#9400) 13m cable (#9411) 67m cable (#9402) 90m cable (#9403) 110m cable (#9404) 13m Cable - Calibrated (#9401)
Description
Sensor type Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield Integrated circuit ambient temperature sensor with six plate radiation shield
Applications
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
  • Wind and solar resource assessment
  • Wind and solar plant operations
  • Meteorological studies
  • Environmental monitoring
Sensor range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F)
Instrument compatibility All NRG loggers All NRG loggers All NRG loggers All NRG loggers All NRG loggers All NRG loggers
Output signal
Signal type Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage Linear analog voltage
Transfer function Temperature (°C) = (Voltage x 44.74364) -40.85555 °C
Temperature (°F) = (Voltage x 80.53855) -41.53999 °F
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Temperature (°C) = (Voltage x 44.74364) - 40.85555 °C
Temperature (°F) = (Voltage x 80.53855) - 41.53999 °F

Note: Transfer function above applies to 4.6-meter cable. For sensors with cable lengths longer than 4.6 meters, subtract 0.002922 °C (0.0052596 °F) per additional meter from the transfer function offset.
Please refer to your calibration report.
Accuracy Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.200 °C (±0.360 °F) Uncertainty (k=2): ±0.164 °C (±0.295 °F)
Output signal range 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC 0.020 to 2.480 V DC
Turn on time <20 ms <20 ms <20 ms <20 ms <20 ms <20 ms
Resolution 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F) 0.0025 °C (0.0045 °F)
Response characteristics
Thermal time constant 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes 5.38 minutes
Power requirements
Supply voltage 5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
5 to 15 V DC

5 V pulsed excitation strongly recommended
Supply current
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
  • 1.2 mA max. (no load on output)
  • SymphoniePRO Pulsed: 0.85 mA average
  • SymphoniePLUS3 Pulsed: 0.43 mA average
Installation
Mounting Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps Attaches to tower with included hose clamps
Tools required
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
  • 8 mm (5/16 inch) nut driver or flat blade (-) screwdriver (to install hose clamps)
  • Sheet metal shears or similar (for trimming hose clamps)
Environmental
Operating temperature range -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F) -40 °C to 70 °C (-40 °F to 158 °F)
Operating humidity range 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH
Lifespan 10 years + 10 years + 10 years + 10 years + 10 years + 10 years +
Physical
Connections Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Wire leads:
  • Signal (clear wire)
  • Ground (black wire)
  • Excitation (red wire)
  • Shield wire for earth ground
Cable length 4.6 m (15 ft) 13 m (42 ft) 67 m (220 ft) 90 m (295 ft) 110 m (361 ft) 13 m (42 ft)
Weight 0.47 kg (1.04 lbs) 0.75 kg (1.65 lbs) 2.53 kg (5.6 lbs) 3.29 kg (7.2 lbs) 3.94 kg (8.7 lbs) 0.75 kg (1.65 lbs)
Dimensions
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
  • Probe only: 51.6 mm (2") height x 12.7 mm (0.5") diameter
  • Radiation shield: 124 mm (4.9") height x 127 mm (5 inches) diameter
Materials
Cable 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket 3 conductor 22 AWG, with overall foil shield and drain wire, chrome PVC jacket
Probe Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled Aluminum, epoxy filled
Shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield UV-stabilized thermoplastic solar radiation shield

Product Support Downloads